Aegis Sterile Nitrile Exam Gloves Long Cuff

Aegis Sterile Nitrile Exam Gloves Long Cuff

  • Brand GloveOn
  • Type Nitrile gloves, Sterile gloves
  • Quantity

    50 pairs per box, 4 boxes per carton

  • Sizes S, M, L, XL
  • Product code SNT154
  • Product Data Sheet Download

Buy direct from Mun

Aegis, like an armour, offers superb hand barrier protection and chemical resistance. Our recommended sterile glove is thicker, with an extended cuff to suit situations which require greater protection.

 

Features

  • Fingertip textured.
  • Powder Free.
  • Not made with natural rubber latex.
  • Chemo drugs tested.
  • Ambidextrous.
  • Long Cuff.
  • Aqua blue colour.
  • Sterilied using gamma irradiation.
Reorder codeSize
SNT154SSSmall
SNT154MMMedium
SNT154LLLarge
SNT154XLX-Large
Glove PropertiesMeasurement (mm)
Length≥280
Thickness at Palm (centre of Palm)0.09 ± 0.02
Thickness at Finger (13mm ± 3mm from tip)0.14 ± 0.02
Physical PropertiesBefore AgeingAfter Ageing
Tensile Strength (MPa)≥18≥16
Elongation (%)≥500≥400
Inspection Levels and AQLInspection LevelAQL
WatertightnessG11.5
Physical DimensionsS24.0
Tensile StrengthS24.0
Visual Inspection (Major)S42.5
Visual Inspection (Minor)S44.0
Particulate ResidueN=5≤2mg/glove
Packaging
Configuration1 pair per pouch
50 pairs per box
4 boxes per carton
Regulatory Compliance
RegulationsARTG 203002
FDA 510(k)
MDD 93/42/EEC
REACH
ROHS Directive 2002/95/EC
EU 10/2011
EC 1935/2004
EU 2016/425
International Standards
StandardsISO 11193-1
ASTM D5151
ASTM D6319
ASTM D6124
ASTM D6978
EN ISO 374 part 1 (Type B), 2, 4 & 5
EN 16523-1
EN 455 part 1, 2 & 3
EN 1186
EN 13130
CEN/TS 14234
ISO 10993 part 5 & 10
HACCP International Certified
Manufacturing Accreditations
AccreditationsISO 9001
ISO 13485
EN ISO 13485
Chemotherapy Drugs and Concentration
(Tested for Resistance to Permeation by Chemotherapy Drugs as per ASTM D6978-05, Test Report PN 138022)
Minimum Breakthrough Detection Time (minutes)
Carmustine (BCNU), 3.3mg/ml (3,300ppm)43.8
Cisplatin, 1.0mg/ml (1,000ppm)>240
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm)>240
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm)>240
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm)>240
Etoposide (Toposar), 20.0mg/ml (20,000ppm)>240
Fluorouracil, 50.0mg/ml (50,000ppm)>240
Methotrexate, 25.0mg/ml (25,000ppm)>240
Mitomycin C, 0.5mg/ml (500ppm)>240
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm)>240
Thiotepa, 10.0mg/ml (10,000ppm)97.8
Vincristine Sulfate, 1.0mg/ml (1,000ppm)>240
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded an Aegis sterile nitrile glove at 43.8 minutes and 97.8 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision.
Aegis, like an armour, offers superb hand barrier protection and chemical resistance. Our recommended sterile glove is thicker, with an extended cuff to suit situations which require greater protection.   Features
  • Fingertip textured.
  • Powder Free.
  • Not made with natural rubber latex.
  • Chemo drugs tested.
  • Ambidextrous.
  • Long Cuff.
  • Aqua blue colour.
  • Sterilied using gamma irradiation.
Reorder codeSize
SNT154SSSmall
SNT154MMMedium
SNT154LLLarge
SNT154XLX-Large
Glove PropertiesMeasurement (mm)
Length≥280
Thickness at Palm (centre of Palm)0.09 ± 0.02
Thickness at Finger (13mm ± 3mm from tip)0.14 ± 0.02
Physical PropertiesBefore AgeingAfter Ageing
Tensile Strength (MPa)≥18≥16
Elongation (%)≥500≥400
Inspection Levels and AQLInspection LevelAQL
WatertightnessG11.5
Physical DimensionsS24.0
Tensile StrengthS24.0
Visual Inspection (Major)S42.5
Visual Inspection (Minor)S44.0
Particulate ResidueN=5≤2mg/glove
Packaging
Configuration1 pair per pouch
50 pairs per box
4 boxes per carton
Regulatory Compliance
RegulationsARTG 203002
FDA 510(k)
MDD 93/42/EEC
REACH
ROHS Directive 2002/95/EC
EU 10/2011
EC 1935/2004
EU 2016/425
International Standards
StandardsISO 11193-1
ASTM D5151
ASTM D6319
ASTM D6124
ASTM D6978
EN ISO 374 part 1 (Type B), 2, 4 & 5
EN 16523-1
EN 455 part 1, 2 & 3
EN 1186
EN 13130
CEN/TS 14234
ISO 10993 part 5 & 10
HACCP International Certified
Manufacturing Accreditations
AccreditationsISO 9001
ISO 13485
EN ISO 13485
Chemotherapy Drugs and Concentration
(Tested for Resistance to Permeation by Chemotherapy Drugs as per ASTM D6978-05, Test Report PN 138022)
Minimum Breakthrough Detection Time (minutes)
Carmustine (BCNU), 3.3mg/ml (3,300ppm)43.8
Cisplatin, 1.0mg/ml (1,000ppm)>240
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm)>240
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm)>240
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm)>240
Etoposide (Toposar), 20.0mg/ml (20,000ppm)>240
Fluorouracil, 50.0mg/ml (50,000ppm)>240
Methotrexate, 25.0mg/ml (25,000ppm)>240
Mitomycin C, 0.5mg/ml (500ppm)>240
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm)>240
Thiotepa, 10.0mg/ml (10,000ppm)97.8
Vincristine Sulfate, 1.0mg/ml (1,000ppm)>240
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded an Aegis sterile nitrile glove at 43.8 minutes and 97.8 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision.