Avalon Biodegradable Nitrile Exam Gloves

View Product

> Biodegrades in landfill conditions
> Fingertip textured
> Powder Free
> Not made with natural rubber latex
> Chemo drugs tested
> Lab chemical tested
> Ambidextrous
> Standard Cuff
> Violet blue colour

Buy through a premium partner

Help improve the environment with GloveOn Avalon biodegradable gloves. Designed to break down normal nitrile gloves in landfill settings, these gloves will take years rather than decades to completely biodegrade. Our unique formulation maintains the high levels of strength and flexibility you’d expect in a nitrile glove, while only allowing the biodegradation process to start once in landfill conditions. Feel confident that GloveOn Avalon will give you the protection you need and help you do your bit for the environment.

Reorder Code Size
BDG121XS X-Small
BDG121SS Small
BDG121MM Medium
BDG121LL Large
BDG121XL X-Large
Glove PropertiesMeasurement (mm)
Length≥230
Thickness at Palm (centre of Palm)0.07 ± 0.02
Thickness at Finger 0.10 ± 0.02
Physical PropertiesBefore AgeingAfter Ageing
Tensile Strength (MPa)≥18≥16
Elongation (%)≥500≥400
Inspection Levels and AQLInspection LevelAQL
WatertightnessG11.5
Physical DimensionsS24.0
Tensile StrengthS24.0
Visual Inspection (Major)S42.5
Visual Inspection (Minor)S44.0
Particulate ResidueN=5≤2mg/glove
Packaging  
Configuration200 gloves per box for XS to L
180 gloves per box for XL
10 boxes per carton
Regulatory Compliance 
RegulationsARTG 164563
FDA 510(k)
MDR 2017/745
REACH
ROHS Directive 2002/95/EC
EU 10/2011
EC 1935/2004
EU 2016/425
International Standards 
StandardsASTM D6319
ASTM D5151
ASTM D6124
ASTM D6978
ASTM D5526
ASTM D5511
EN ISO 374-1 (Type C)
EN 374 part 2, 4 & 5
EN 16523-1
EN 420
EN 455 part 1, 2, 3
EN 1186
EN 13130
CEN/TS 14234
ISO 10993 part 5, 10, 11
HACCP International Certified
Manufacturing Accreditations 
AccreditationsISO 9001
ISO 13485
EN ISO 13485
Chemotherapy Drugs and Concentration
(Tested for Resistance to Permeation by Chemotherapy Drugs as per ASTM D6978-05-Test Report PN 145460)
Minimum Breakthrough Detection Time (minutes)
Carmustine (BCNU), 3.3mg/ml (3,300ppm)22.2
Cisplatin, 1.0mg/ml (1,000ppm)>240
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm)>240
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm)>240
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm)>240
Etoposide (Toposar), 20.0mg/ml (20,000ppm)>240
Fluorouracil, 50.0mg/ml (50,000ppm)>240
Methotrexate, 25.0mg/ml (25,000ppm)>240
Mitomycin C, 0.5mg/ml (500ppm)>240
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm)>240
Thiotepa, 10.0mg/ml (10,000ppm)66.1
Vincristine Sulfate, 1.0mg/ml (1,000ppm)>240
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded a Celeste nitrile glove at 22.2 minutes and 66.1 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision.