Hartson Nitrile Exam Gloves Long Cuff

Hartson Nitrile Exam Gloves Long Cuff

  • Brand GloveOn
  • Type Nitrile Gloves
  • Quantity

    100 gloves per box (XS-XL)
    80 gloves per box (XXL)
    10 boxes per carton

  • Sizes XS, S, M, L, XL, XXL
  • Product code HTS111
  • Product Data Sheet Download

Buy direct from Mun

GloveOn Hartson allows you to feel better protected to give you the confidence to perform the tasks at hand. With an extended cuff for superior coverage, high tensile strength and great chemical resistance backed by rigorous testing, Hartson provides exceptional levels of safety. Its formulation also caters for tasks needing first-rate dexterity thanks to its superb elongation which also delivers excellent comfort.

 

Features

  • Fingertip textured.
  • Powder Free.
  • Not made with natural rubber latex.
  • Chemo drugs tested.
  • Lab chemical tested.
  • Ambidextrous.
  • Long Cuff.
  • Aqua blue colour.
Reorder codeSize
HTS111XSX-Small
HTS111SSSmall
HTS111MMMedium
HTS111LLLarge
HTS111XLX-Large
HTS111XXLXX-Large
International Standards
StandardsASTM D6319
ASTM D5151
ASTM D6124
ASTM D6978
EN ISO 374-1 (Type B)
EN 16523-1
EN 374 part 2, 4 & 5
EN 420
EN 455 part 1, 2, 3 & 4
EN 1186
EN 13130
CEN/TS 14234
NFPA 1999
ISO 10993 part 5 & 10
HACCP International Certified
Manufacturing Accreditations
AccreditationsISO 9001
ISO 13485
EN ISO 13485
Chemotherapy Drugs and Concentration
(Tested for Resistance to Permeation by Chemotherapy Drugs as per ASTM D6978-05, Test Report PN 101567)
Minimum Breakthrough Detection Time (minutes)
Carmustine (BCNU), 3.3mg/ml (3,300ppm)15.1
Cisplatin, 1.0mg/ml (1,000ppm)>240
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm)>240
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm)>240
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm)>240
Etoposide (Toposar), 20.0mg/ml (20,000ppm)>240
Fluorouracil, 50.0mg/ml (50,000ppm)>240
Methotrexate, 25.0mg/ml (25,000ppm)>240
Mitomycin C, 0.5mg/ml (500ppm)>240
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm)>240
Thiotepa, 10.0mg/ml (10,000ppm)30.8
Vincristine Sulfate, 1.0mg/ml (1,000ppm)>240
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded a Maverick LC nitrile glove at 15.1 minutes and 30.8 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision.
Glove PropertiesMeasurement (mm)
Length≥280
Thickness at Palm (centre of Palm)0.10 ± 0.02
Thickness at Finger (13mm ± 3mm from tip)0.13 ± 0.02
Thickness at Cuff (25mm from cuff edge)0.08 ± 0.02
Physical PropertiesBefore AgeingAfter Ageing
Tensile Strength (MPa)≥18≥16
Elongation (%)≥500≥400
Inspection Levels and AQLInspection LevelAQL
WatertightnessG11.5
Physical DimensionsS24.0
Tensile StrengthS24.0
Visual Inspection (Major)S42.5
Visual Inspection (Minor)S44.0
Particulate ResidueN=5≤2mg/glove
Packaging
Configuration100 gloves per box
10 boxes per carton
Regulatory Compliance
RegulationsARTG 164563
MDD 93/42/EEC
REACH
ROHS Directive 2002/95/EC
EU 2016/425
GloveOn Hartson allows you to feel better protected to give you the confidence to perform the tasks at hand. With an extended cuff for superior coverage, high tensile strength and great chemical resistance backed by rigorous testing, Hartson provides exceptional levels of safety. Its formulation also caters for tasks needing first-rate dexterity thanks to its superb elongation which also delivers excellent comfort.   Features
  • Fingertip textured.
  • Powder Free.
  • Not made with natural rubber latex.
  • Chemo drugs tested.
  • Lab chemical tested.
  • Ambidextrous.
  • Long Cuff.
  • Aqua blue colour.
Reorder codeSize
HTS111XSX-Small
HTS111SSSmall
HTS111MMMedium
HTS111LLLarge
HTS111XLX-Large
HTS111XXLXX-Large
International Standards
StandardsASTM D6319
ASTM D5151
ASTM D6124
ASTM D6978
EN ISO 374-1 (Type B)
EN 16523-1
EN 374 part 2, 4 & 5
EN 420
EN 455 part 1, 2, 3 & 4
EN 1186
EN 13130
CEN/TS 14234
NFPA 1999
ISO 10993 part 5 & 10
HACCP International Certified
Manufacturing Accreditations
AccreditationsISO 9001
ISO 13485
EN ISO 13485
Chemotherapy Drugs and Concentration
(Tested for Resistance to Permeation by Chemotherapy Drugs as per ASTM D6978-05, Test Report PN 101567)
Minimum Breakthrough Detection Time (minutes)
Carmustine (BCNU), 3.3mg/ml (3,300ppm)15.1
Cisplatin, 1.0mg/ml (1,000ppm)>240
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm)>240
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm)>240
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm)>240
Etoposide (Toposar), 20.0mg/ml (20,000ppm)>240
Fluorouracil, 50.0mg/ml (50,000ppm)>240
Methotrexate, 25.0mg/ml (25,000ppm)>240
Mitomycin C, 0.5mg/ml (500ppm)>240
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm)>240
Thiotepa, 10.0mg/ml (10,000ppm)30.8
Vincristine Sulfate, 1.0mg/ml (1,000ppm)>240
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded a Maverick LC nitrile glove at 15.1 minutes and 30.8 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision.
Glove PropertiesMeasurement (mm)
Length≥280
Thickness at Palm (centre of Palm)0.10 ± 0.02
Thickness at Finger (13mm ± 3mm from tip)0.13 ± 0.02
Thickness at Cuff (25mm from cuff edge)0.08 ± 0.02
Physical PropertiesBefore AgeingAfter Ageing
Tensile Strength (MPa)≥18≥16
Elongation (%)≥500≥400
Inspection Levels and AQLInspection LevelAQL
WatertightnessG11.5
Physical DimensionsS24.0
Tensile StrengthS24.0
Visual Inspection (Major)S42.5
Visual Inspection (Minor)S44.0
Particulate ResidueN=5≤2mg/glove
Packaging
Configuration100 gloves per box
10 boxes per carton
Regulatory Compliance
RegulationsARTG 164563
MDD 93/42/EEC
REACH
ROHS Directive 2002/95/EC
EU 2016/425

Learn full technical specifications of all products

Product Data Sheets

Learn more