Matador Nitrile Exam Gloves Long Cuff

View Product

> Fingertip textured
> Powder free
> Not made with natural rubber latex
> Chemo drugs tested
> Lab chemical tested
> Ambidextrous
> Long cuff
> Sky blue colour

Buy through a premium partner

GloveOn Matador is built with quality, consistency and reliability in an 8ml nitrile glove. With GloveOn Matador, users can take confidence in wearing a stronger glove to shape their performance in their work duties.

 

Reorder Code Size
NTR18SS Small
MTR151MM Medium
NTR18LL Large
MTR151XL X-Large

 

Glove PropertiesMeasurement (mm)
Length≥280
Thickness at Palm (centre of Palm)0.20 ± 0.04
Thickness at Finger (13mm ± 3mm from tip)0.28 ± 0.04
Thickness at Cuff (25mm from cuff edge)0.14 ± 0.04
Physical PropertiesBefore AgeingAfter Ageing
Tensile Strength (MPa)≥18≥16
Elongation (%)≥500≥400
Inspection Levels and AQLInspection LevelAQL
WatertightnessG11.5
Physical DimensionsS24.0
Tensile StrengthS24.0
Visual Inspection (Major)S42.5
Visual Inspection (Minor)S44.0
Particulate ResidueN=5≤2mg/glove
Packaging  
Configuration50 gloves per box for S to XL
45 gloves per box for XXL
10 boxes per carton
Regulatory Compliance 
RegulationsARTG 164563
FDA 510(k)
MDD 93/42/EEC
REACH
ROHS Directive 2002/95/EC
EU 2016/425
International Standards 
StandardsAS/NZS 4011-1
ASTM D6319
ASTM D5151
ASTM D6124
ASTM D6978
EN 420
EN 16523-1
EN ISO 374-1 (Type A)
EN 374 part 2, 4 & 5
ISO 11193-1
EN 455 part 1, 2, 3 & 4
ISO 10993 part 5 & 10
HACCP International Certified
Manufacturing Accreditations 
AccreditationsISO 9001
ISO 13485
Chemotherapy Drugs and Concentration
(Tested for Resistance to Permeation by Chemotherapy Drugs as per ASTM D6978-05, Test Report PN 107200B)
Minimum Breakthrough Detection Time (minutes)
Carmustine (BCNU), 3.3mg/ml (3,300ppm)90.6
Cisplatin, 1.0mg/ml (1,000ppm)>240
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm)>240
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm)>240
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm)>240
Etoposide (Toposar), 20.0mg/ml (20,000ppm)>240
Fluorouracil, 50.0mg/ml (50,000ppm)>240
Methotrexate, 25.0mg/ml (25,000ppm)>240
Mitomycin C, 0.5mg/ml (500ppm)>240
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm)>240
Thiotepa, 10.0mg/ml (10,000ppm)165.8
Vincristine Sulfate, 1.0mg/ml (1,000ppm)>240
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded Matador nitrile glove at 90.6 minutes and 165.8 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision.
EN ISO 374-1:2016 Type APermeation Performance Level
Sulphuric Acid 96% (L)2
n-Heptane (J)3
Sodium Hydroxide 40% (K)6
Ammonium hydroxide 25% (O)4
Formaldehyde 37% (T)6
Hydrogen peroxide 30% (P)6
Hydrofluoric acid 40% (S)2

Download Specifications Sheet

 

FEATURED SELLERS
Dentavision
Regional Health Care Group
Protat Logo 2
EBOS Healthcare
Alpha Medical Supplies
Team Medical
Glass Vials Logo
SSS Australia
McFarlane Logo FA-Hero
Vital Medical Supplies
FIND YOUR NEAREST SELLER