Maverick Nitrile Exam Gloves

View Product

> Fingertip textured
> Powder Free
> Not made with natural rubber latex
> Chemotherapy drugs tested
> Lab chemical tested
> Ambidextrous
> Standard Cuff
> Aqua blue colour


GloveOn Maverick is the all-round nitrile glove which has proven itself in medical, laboratory and industrial use. Tested for tensile strength and chemical resistance, GloveOn Maverick’s elastic formulation mimics the donning properties of latex gloves in softness, stretchability, tactility and comfort fit.

 

Reorder CodeSize
NTR28XSX-Small
NTR28SSSmall
NTR28MMMedium
NTR28LLLarge
NTR28XLX-Large

 

Glove PropertiesMeasurement (mm)
Length≥230
Thickness at Palm (centre of Palm)≥0.08
Thickness at Finger (13mm ± 3mm from tip)≥0.11
Physical PropertiesBefore AgeingAfter Ageing
Tensile Strength (MPa)≥18≥16
Elongation (%)≥500≥400
Inspection Levels and AQLInspection LevelAQL
WatertightnessG11.5
Physical DimensionsS24.0
Tensile StrengthS24.0
Visual Inspection (Major)S42.5
Visual Inspection (Minor)S44.0
Particulate ResidueN=5≤2mg/glove
Packaging 
Configuration200 gloves per box for XS to L
180 gloves per box for XL
10 boxes per carton
Regulatory Compliance 
RegulationsARTG 164563
MDD 93/42/EEC
REACH
ROHS Directive 2002/95/EC
EU 10/2011
EC 1935/2004
EU 2016/425
International Standards 
StandardsAS/NZS 4011-1
ASTM D5151
ASTM D6124
ASTM D6319
ASTM D6978
EN ISO 374-1 (Type B)
EN 16523-1
EN 374 part 2, 4 & 5
EN 455 part 1, 2, 3 & 4
ISO 10993 part 10
HACCP Certified
Manufacturing Accreditations 
AccreditationsISO 9001
ISO 13485
EN ISO 13485
Chemotherapy Drugs and Concentration
(Tested for Resistance to Permeation by Chemotherapy Drugs as per ASTM D6978-05, Test Report PN 104145B)
Minimum Breakthrough Detection Time (minutes)
Carmustine (BCNU), 3.3mg/ml (3,300ppm)15.3
Cisplatin, 1.0mg/ml (1,000ppm)>240
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm)>240
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm)>240
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm)>240
Etoposide (Toposar), 20.0mg/ml (20,000ppm)>240
Fluorouracil, 50.0mg/ml (50,000ppm)>240
Methotrexate, 25.0mg/ml (25,000ppm)>240
Mitomycin C, 0.5mg/ml (500ppm)>240
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm)>240
Thiotepa, 10.0mg/ml (10,000ppm)46.3
Vincristine Sulfate, 1.0mg/ml (1,000ppm)>240
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded a Maverick nitrile glove at 15.3 minutes and 46.3 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision.